1.We are not responsible for any custom duty or import tax fee , it is buyer’s responsibility, if you have any problem, pls contact us freely. Regardless of the buyer from which country or region you are in, when the declared value of the goods exceeds a certain value (each country or region is different, please consult the local customs), import tariffs will be generated. The tariff must be paid by the buyer. If you are not willing to pay customs duty, please kindly do not buy products in our store!
2.We will fill in the declared value according to the actual payment amount. You can contact us and ask us to fill in a lower declared value, but the resulting customs deduction risk will be borne by you!
Description:
The ES1000 Dry Bath Incubator is a semi-conductor controlled heating and amp; cooling instrument with automatic temperature control design. The flexible timer, constant temperature function and multi-point operation mode make it a unique and an ideal lab instrument.
Features:
2. Has combined temperature control system and block system. Each block has a built-in temperature sensor and heating/cooling unit, ensuring that temperature control is more accurate and the heating speed is much faster.
3. Interchangeable, auto-recognized blocks.
4. Adjustable heating lid. Temperature of heating lid can be controlled.
5. Multi-point(max. 5 points) and Multi-cycle( Max.99 times) operation modes are provided.
6. Auto restart in case of power failure.
7. Over-heating protection device is included.
8. Built-in temperature calibration function.
Parameters:
Project | Parameters | Parameters |
Block | ES series | ESC series |
Temp. setting range | 0℃~100℃ | -10℃~100℃ |
Temp. control range | RT+5℃~100℃ | RT-25℃~100℃ |
Timing range | 1sec~99h59min/∞ | 1sec~99h59min/∞ |
Temp. accuracy | ≤±0.3℃@37℃ | ≤±0.3℃@37℃ |
Display accuracy | 0.1℃ | 0.1℃ |
Temp. accuracy | ≤±0.3℃@37℃ | ≤±0.3℃@37℃ |
Heating time | ≤12min(from 25℃ to 100℃) | ≤12min(from 25℃ to 100℃) |
Cooling time | — | ≤12min(from 100℃ to 25℃) |
Cooling time | — | ≤25min(from RT. to RT.-25℃) |
Heating lid temp. setting range | OFF~+10℃ | OFF~+10℃ |
Temp. accuracy | ≤±0.5℃ | ≤±0.5℃ |
Heating lid heating time | ≤10min(from 25℃ to 100℃) | ≤10min(from 25℃ to 100℃) |
AUTO-4℃ | — | Yes* |
Multi points running | Yes(Max 5points) | Yes(Max 5points) |
Multi points running circularly | Yes(Max 99 times) | Yes(Max 99 times) |
Auto running | Yes | Yes |
Auto heating | Yes | Yes |
Auto resume to run | Yes | Yes |
Voltage | AC110V or 220V,50/60Hz | AC110V or 220V,50/60Hz |
Power | 150W | 150W |
Fuse | 250V 3A φ5×20 | 250V 3A φ5×20 |
Dimension(mm) | 300×200×210 | 300×200×210 |
Weight(kg) | 4.0 | 4.7 |
Testcondition: RT25℃ ± 2℃, block is 35×1.5ml, use mercurial thermometer, accuracy is ±0.1℃ |
Optional Blocks:
Type |
Capacity |
Temp. range |
ESC-01 |
35×2.0ml centrifuge tube |
RT-25℃~100℃ |
ESC-02 |
35×1.5ml centrifuge tube |
RT-25℃~100℃ |
ESC-03 |
54×0.5ml centrifuge tube |
RT-25℃~100℃ |
ESC-04 |
96×0.2ml centrifuge tube |
RT-25℃~100℃ |
ESC-05 |
96×0.2ml Elisa plate |
RT-25℃~100℃ |
ES-06 |
35×2.0ml centrifuge tube |
RT+5℃~100℃ |
ES-07 |
35×1.5ml centrifuge tube |
RT+5℃~100℃ |
ES-08 |
54×0.5ml centrifuge tube |
RT+5℃~100℃ |
ES-09 |
96×0.2ml centrifuge tube |
RT+5℃~100℃ |
ES-10 |
96×0.2ml Elisa plate |
RT+5℃~100℃ |